Double labeling with two Ultra Small Reagents
Aurion has once more confirmed its leading
role in immunogold technology through a publication in the latest issue of the
Journal of Histochemistry and Cytochemistry 49(3): 279-283 (2001).
In
this publication it was demonstrated for the first time in history that it is
possible to perform a double labeling experiment using two ultra small gold
conjugates and differential silver enhancement using Aurion R-Gent SE-EM, the
enhancement reagent of choice for electron microscopy
applications.
Pre-embedding double labeling of GFAP (small
particles) and synaptophysin (large particles) in brain tissue using two
ultrasmall gold conjugates and silver enhancement. Courtesy Mrs. Hong Yi,
Emory University Atlanta
This approach was successful thanks to the excellent and tuned
qualities of the reagents involved:
- the high penetration
characteristics of Aurion's Ultra Small Immunogold Reagents,
- the low
viscosity and high efficiency of the silver enhancement reagents
and
- the excellent homogeneity of the resulting silver particles,
providing the basis to distinguish particle sizes as dependent on silver
enhancement times.
One more item was required: the Enhancement
Conditioning Solution (ECS)
What is ECS intended for? ECS is used as a
bridge solution between the gold incubation and the silver enhancement.
Before the silver enhancement step in a single labeling the specimen is
fixed with glutaraldehyde and washed with distilled water. The fixation prevents
ultrastructural defects that would result from the water wash of a mildly fixed
vibratome section. The water wash step is necessary for compatibility of the
silver enhancement step.
Obstacles in Double LabelingWhen performing a
double labeling with ultrasmall gold conjugates a few obstacles have to be
overcome:
- a fixation step after the first labeling before silver
enhancing can not be performed as this would make it impossible to do a second
labeling,
- Washing the specimen in distilled water without a fixation
step affects the morphology of the specimen in a negative way
- Washing
in incubation buffer is not compatible with silver
enhancement.
Aurion developed, in close co-operation with Hong Yi
from Emory University, Aurion ECS (Enhancement Conditioning Solution) which
replaces the fixation and water wash step. The product is compatible with
buffer and silver enhancer and does not affect morphology.
Aurion ECS in Double
LabelingSchematically this is the sequence of steps for double
labeling using ultrasmall gold conjugates:
Labeling 1: - gold
incubation
- washing in incubation buffer
- ECS
- silver
enhancement
- ECS + thiosulphate
- ECS
Labeling
2:- gold incubation
- washing in incubation
buffer
- ECS
- silver enhancement
Please note that
Aurion ECS can only be used with
Aurion R-Gent
SE-EM, because the components of ECS are tuned to the components of R-Gent
SE-EM.
Aurion as well as leading researchers in the field are convinced
that these new possibilities will facilitate and simplify immuno electron
microscopic research in the bio-medical field.
© Aurion 2007 - 2010